What was found
SHEAR FITTING AT STATION 540 AND RBL 6.14 IS CRACKED. REMOVED AND REPLACED SHEAR FITTING AT BS 540, RBL 6.14 IAW SRM 51-40-02 AND BAC DWG 111A2000 REV ORIG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SHEAR FITTING AT STATION 540 AND RBL 6.14 IS CRACKED. REMOVED AND REPLACED SHEAR FITTING AT BS 540, RBL 6.14 IAW SRM 51-40-02 AND BAC DWG 111A2000 REV ORIG.