What was found
ENG 1 EGT EXCEEDENCE ON CLIMB OUT. NORMAL IND. WITH REDUCED POW ER NO EXCEEDANCE FOUND IN ENGINE 1 EXCEEDANCE. ENG TEMP WAS AT 942 CELCIUS FOR 84 SECONDS. PERFORMED AMM 71-00-00-800-804-F00 INSPECTION AFTER ENGINE OPS ABOVE LIMITS AND HIGH ENGINE STRESS STEP F ENGINE OVER TEMP IN CLIMB. PER GRAPH IN FIG 604 NO MAINTENANCE ACTION IS NECESSARY REF AMM 71-00-00-800-804-F00 STEP F (5) ACCOMPLISHED VISUAL INSPECTION OF NR 1 ENGINE INLET AND ENGINE EXHAUST. NO DAMAGE NOTED FLAGGING SDR DUE TO ENG 1 EGT EXCEEDANCE ON CLIMB OUT, AIR RETURN. FOUND TO BE WITHIN LIMITS. AFTER INTERROGATION NO EXCEEDANCE FOUND. FOUND TO BE WITHIN LIMITS. AFTER INTERROGATION NO EXCEEDANCE FOUND.