What was found
CABIN R-2 DOOR CORROSION AT FR 68 BETWEEN STR 22 AND STR 23. EVALUATED CORROSION AT R2 DOOR FR68 RT BETWEEN STR 22 AND 23 IAW SRM 53-41-12-283-001, CORROSION FOUND TO BE OUT OF LIMITS, MAXI MUM REWORK ALLOWED .02 IN, FOUND DAMAGE TO BE .025 IN. IAW SRM 5 3-41-12-283-001 FIG 1 FLOW CHART, ALLOWABLE REWORK ON FR68 MORE THAN 50% MATERIAL LOSS REQUIRES REPAIR PRINCIPLE II. PERFORMED P RINCIPLE II CORROSION REPAIR IAW SRM 53-41-12-300-002 THIS TASK IS A CATEGORY B REPAIR. IAW SRI 53-41-12-205-003 TABLE 1.