What was found
CRACK AT UPPER L/1 DOOR FRAME LOWER CORNER STA. 312 STR 5-6L. ACCOMPLISHED REPAIR OF FUSESALGE FRAME AT STA 312 AT STR 5L AND 6L AS PER SRM 53-10-07-2R-1, PENDING ESFR ENTRY, DIP REQUIRED AS PER TABLE 202,INSPECTION THRESHOLD 50,000 FLIGHT CYCLES OR 12,000 FLIGHT CYCLES AFTER REPAIR INSTALLATION, WHICHEVER COMES LATER, INSPECTION INTERVAL OF 12,000 FLIGHT CYCLES FOR HFEC.