Service difficulty report · Warning Message · Boeing 757224

Difficulty date
November 1, 2025
Submitted
November 4, 2025
Operation
Air carrier
Aircraft
N18119
Make and model
Boeing 757224
Aircraft serial
27561
Aircraft time
97,962 hours, 23,240 cycles
Part
Warning Message
Condition
Illuminated
Location
Fuel Pump
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RIGHT CENTER FUEL PUMP STILL DISPLAYS ON FLOW BAR WHEN DESELECTE D PRESS LIGHT NOT ON MECHANICAL WINDOW THAT SHOWS/HIDES FLOW BAR INOP. PULLED AND COLLARED R FUEL OVRD PUMP BREAKER ON P6. INSTALLED TAPE OVER CENTER FUEL PUMP RIGHT SWITCH, WHEN CLEARING DEFERRAL, REMOVE TAPE. INOP STICKER APPLIED ADJACENT TO SWITCH. REQUEST MEL 2822H. MEL 2822H REJECTING AS NO MEL PER DISP FOUND RIGHT CENTER FUEL PUMP SWITCH FLOW BAR SHUTTER OFF TRACK NOT ALLOWING SHUTTER TO CLOSE....REINSTALLED SHUTTER ON TRACK AND NOW SWITCH OPERATES NORMALLY....ACCOMPLISHED FUEL MANAGEMENT CONTROL PANEL TEST IAW AMM 28-22-14-714-014....ALL CHECKS GOOD