What was found
RAMP REPORTED A DENT UNDER CAPT WINDOW. UPON FURTHER INVESTIGATION FOUND TO BE 2 DENTS. UPPER DENT FOUND TO BE OUT OF LIMITS, DAMAGE IS LOCATED ON STRINGER AND FRAME REF SRM 53-11-11-283-012. ACCOMPLISHED DOUBLER REPAIR IAW ECRA 5311-03412, SRM 53-11-11-283-012, & 53-11-11-300-041.