What was found
FOUND DAMAGE TO PNEU ACCESS PANEL DOOR LATCHES WORN BEYONG LIMITS.PERFORMED STEPS 4A THROUGH 4E IRW SRM 57-10-13-2R-3. PERFORMED STEPS 4F AND 4G HFEC OF CUTOUT AND HFEC HOLE PROBE COMMON TO THE REPAIR AREA. NO FURTHER DEFECTS NOTED REF SRM 57-10-13-2R-3 AND 737 NDT PT.6 51-00-00 PROC 23 AND PROC 16 FLAP PEEN IAW SRM 57-10-13-2R-3. STEP H 1-3. C. FABRICATED REPAIR PARTS IAW SRM 57-10-13-2R-3 STEP 4.I. INSTALLED REPAIR PARTS IAW SRM 57-01-13-2R-3 STEPS 4.J THROUGH 4.N(4). LATCH COMMON TO REPAIR NEEDS TO BE SHIMMED. NEW SEAL AND SEAL RETAINER INSTALLED IAW SRM 57-10-13-2R-3. ALL WORK ACCOMPLISHED IAW SRM 57-10-13-2R-3.