As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EPSU INT LOAD FWD L MSG DURING CABIN EMERGENCY LIGHT TEST PERFORMED WIRE CHECKS PER ASM 33-51-01 SCH 01, PAGE 169. FOUND RESISTANCE AT PIN T OF 10WL EPSU CONNECTOR TO GROUND TO BE 27K OHMS. SUSPECT BAD LIGHT INSIDE ESCAPE SLIDE FWD DOOR LH. REMOVED ESCAPE SLIDE-RAFT PACK ASSEMBLY IN REF WITH AMM 25-62-44-000-012-A .