As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RIGHT BLEED TRIP OFF LIGHT PERFORMED PNUEMATIC HEALTH CHECK PER MM 36-11-00-700-801. FOUND PRSOV,BAR, AND PRECOOLER CONTROL VALVE OUT OF LIMITS. REMOVED AND REPLACED BAR PER MM 36-11-03. REMOVED AND REPLACED PSROV PER MM 36-11-04. R/R PRECOOLER CONTROL VALVE PER MM PER MM 36-12-02. PEFORMED CROSSOVER BLEED SCHEDULE PER MM 36-11-00. BLEED SCHEDULE NORMAL DURING ALL SETTINGS.