What was found
MAIN CABIN STA 540 FLOORBEAM CRACKED BETWEEN BL0 AND LBL 24. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-40-02-0G-0, & DWG 143A5240. DRILLED FASTENER HOLES FOR FLOOR PANEL IAW SRM 51-40-05-0G-0, DWG 144A5800 REV B, & DWG 144A5810.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN STA 540 FLOORBEAM CRACKED BETWEEN BL0 AND LBL 24. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-40-02-0G-0, & DWG 143A5240. DRILLED FASTENER HOLES FOR FLOOR PANEL IAW SRM 51-40-05-0G-0, DWG 144A5800 REV B, & DWG 144A5810.