What was found
FWD CARGO COMPARTMENT RT ZEE CHANNEL POSSIBLE CORROSION BTW BS 500D - 500L. REMOVED, FABRICATED, LOCATED, DRILLED, AND PERFORMED COUTERSINK ON FWD CARGO RT ZEE CHANNEL. APPLIED ALODINE A ND PRIMER ALL WORK DONE IAW SRM 51-40-02-0G-0, 53- 00-53-2R-5, 51-40-05-0G-0, 51-40-08-0G-0, 51-20-01-0G-0 AMM 51-2 1-72-370-804, &20-60-07-913-801.