What was found
CRACKED FLOOR SUPPORT AT LH, ON STA 540, BTW LBL 47 AND 64 AT W ING BOX CENTER SECTION (REF AAR NR 1000058054) FABRICATE, LOCATED, DRILLED AND INSTALLED NEW PLATE ON FLOOR SUPPORT BTW LBL 47 TO LBL 64 STA 540 IAW B737-800 DWG 145A5240 AND SRM 51-40-02-0G-0, GMM 07-35-05 CAT 3. ALL WORK CAPTURED ON AAR RFD N/R 1000058054 FABRICATE, LOCATED, DRILLED AND INSTALLED NEW PLATE ON FLOOR SUPPORT BTW LBL 47 TO LBL 64 STA 540 IAW DWG 145A5240 AND SRM 51-40-02-0G-0, GMM 07-35-05 CAT 3.