What was found
ENGINE ANTI-ICE AMBER LIGHT ON NR 2 ENGINE CAME ON. PER CREW ISSUE PRESENTED DURING CLIMB. REF FIM 36-21011 PILOT TRIED TO RECYCLE NO HELP. COMPLIED WITH MEL HPSOV IS DEACTIVATED CLOSED. MAINT PROCEDURE COMPLIED WITH. CB FOR NR 2 COLLARED. MSG INHIBITED. PLACARD INSTALLED. *DM* SEE FIM 36-21 TSK 802 FOR NOTED MSG 36-21011. REPLACED PRSOV VALVE AND PRESSURE SENSOR. REF. FIM 36-21 TASK802, AMM 36-11-04/401, AMM 36-11-05/401. RESTORED SYSTEM TO NORMAL. OPS CHECKED AND LEAK CHECKED GOOD.