What was found
EPSU BATTERY EMER L, FAULT MESSAGE FROM CIDS WHILE CONDUCTING EMER LIGHT SYSTEM TEST. REMOVED AND REPLACED EPSU BATTERY 11WL, IAW AMM 33-51-38-000-002-A, 33-51-38-400-002-A. OPS CHECKED GOOD, NO FAULT MESSAGES OR DEFECTS NOTED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EPSU BATTERY EMER L, FAULT MESSAGE FROM CIDS WHILE CONDUCTING EMER LIGHT SYSTEM TEST. REMOVED AND REPLACED EPSU BATTERY 11WL, IAW AMM 33-51-38-000-002-A, 33-51-38-400-002-A. OPS CHECKED GOOD, NO FAULT MESSAGES OR DEFECTS NOTED.