What was found
FIRST CLASS EEPL LIGHTING AND R1 DOOR EMERGENCY LIGHTING INOP. SUPPORT TASK NSA EMX N/R 00159. REMOVED FWD ENTRY PANEL IAW AMM 25-21-71-000-807 SUBTASK 25-21-71-010-010. REMOVED BATTERY PACK AT BATTERY SUPPLY UNIT M1674 IAW AMM 33-51-06. INSTALLED SERVICEABLE BATTERY PACK AT BATTERY SUPPLY UNIT N1674 IAW AMM 33-51- 06. PERFORMED OPS TEST OF NEW SERVICEABLE BATTERY PACK IAW AMM 33-51-06 SUBTASK 33-51-06-710-004. TEST PASSED. RE-INSTALLED FWD ENTRY PANEL IAW AMM 25-21-71 SUBTASK 25-21-71-410-009. REMOVED FWD ENTRY PANEL IAW AMM 25-21-71-000-807, SUBTASK 25-21-71-010-010. REMOVED BATTERY PACK AT BATTERY SUPPLY UNIT M1674 IAW AMM 33-51- 06. INSTALLED SERVICEABLE BATTERY PACK AT BATTERY PACK UNIT M1674 IAW AMM 33-51-06. PERFORMED OPS TEST OF NEW SERVICEABLE BATTERY PACK IAW AMM 33-51-06, SUBTASK 33-51-06-710-004. TEST PASSED. RE-INSTALLED FWD ENTRY PANEL IAW AMM 25-21-71 SUBTASK 25-21-71-410-009.