What was found
CABIN FLOOR INTERCOSTAL BS 344 - 360, BL 0 UPPER SURFACE CRACKED AREA. REMOVED AND REPLACED UPPER CHORD IAW SRM 51-40-02-0G-0 AND DWG 141A5400.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FLOOR INTERCOSTAL BS 344 - 360, BL 0 UPPER SURFACE CRACKED AREA. REMOVED AND REPLACED UPPER CHORD IAW SRM 51-40-02-0G-0 AND DWG 141A5400.