What was found
CORROSION AFT WET AREA FLOORBEAM BS 986.5 AROUND FASTENER HOLES BETWEEN RBL 4 AND 44. ACCOMPLISHED REPAIR IAW SRM 53-70-51-2R-4, AND SRM 51-40-02-0G-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION AFT WET AREA FLOORBEAM BS 986.5 AROUND FASTENER HOLES BETWEEN RBL 4 AND 44. ACCOMPLISHED REPAIR IAW SRM 53-70-51-2R-4, AND SRM 51-40-02-0G-0.