What was found
EMERGENCY LIGHTS - OPERATIONAL CHECK EMERGENCY LIGHTS OPERATIONAL CHECK - AT RIGHT OVERWING EXIT, 3EA EXIT LIGHTS DID NOT ILLUMINATE DURING EMERGENCY LIGHT TEST; BOTH FORWARD AND AFT ABOVE DOOR EXIT LIGHTS, AND ONE LOWER EXIT LIGHT AT AFT OVERWING EXIT DOOR. REPLACED EMERGENCY POWER SUPLY BATTERY IN REF TO AMM TASK 33-51-06-960-805. OPS CHECK GOOD ALL EMERGENCY EXIT SIGNS LIGHT PROPERLY.