What was found
(SDR)(19-0671-1-0004) CUSTOMER REQUEST - DO A HIDDEN DAMAGE INSP ECTION AT NUMBER 2 ENG DUE TO A BORESCOPE PLUG MISSING AT THE LP COMPRESSOR I/B UPR FAIRING AREA. REF NRC 138155. SDR WAS ENTERED. ACCOMPLISHED E2 LP COMPRESSOR FAIRING AREA HIDDEN DAMAGE INSPECT ION IAW B757 AMM 03-72-62-200-802. PERFORMED DVI AT NO 2 ENG I/B T/R BIFURICATION DUCT IAW B757 AMM 03-78-30-200-801. NO DAMAGE NOTED AT HIGH SPEED GEAR BOX RADIAL DRIVE AREA OR T/R BIFURCATIO N DUCT. SDR:4332. REF NRC 138155.