What was found
SHORTLY AFTER T/O L FMC FAILURE. ACCOMPLISHED NON-NORMAL. NO HEL P FMC AND DISPLAY UNIT ORDERED TO B29. NO FMC FAULTS AT CURRENT TIME OR IN RECENT HISTORY. ACOMPLISHED FMC OPERATIONAL TEST AND SYSTEM TEST REF AMMS 34-61-00-710-801 AND 34-61-00-730-801. INCLUDING BOTH AIMS' OPERATIONAL TEST/ RESET REF AMM TASK 31-41-00-710-801.NO FAULTS. REINSTALLED NAV COMPUTER, PRIMA IAW AMM TASK 34-61-00-470-801. FMC IS NOT A INDIVUAL UNIT TO BE INSTALLED. REF SDS 34-61-00-002. PER MANAGEMENT REQUEST INSTALLED LEFT PFC PER AMM TASK 27-02-01-000/400-801. S/W AND OPS TESTS GOOD. NO PFC FAULTS.