What was found
FOUND TWO DENTS IN AFT CABIN WET AREA GALLEY SUPPORT FLOOR WEB, LBL 7 & 12, BS 1016. REMOVED AND REPLACED THE WEB BS 1016 & LBL 3.59 - 27.95 IAW SRM 51-40-02-0G-0 & DWG 147A5700.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND TWO DENTS IN AFT CABIN WET AREA GALLEY SUPPORT FLOOR WEB, LBL 7 & 12, BS 1016. REMOVED AND REPLACED THE WEB BS 1016 & LBL 3.59 - 27.95 IAW SRM 51-40-02-0G-0 & DWG 147A5700.