What was found
MAIN MID CABIN FLOOR UNDER FLOOR PANEL 241 GF BETWEEN BS 1160 & 1180, BL 0, SUPPORT BRACKET HAS 2 CRACKS. FABRICATED IAW DRAWING. REMOVED REPLACED IAW SRM 51-70-11-OG-0, AND REINSTALLED MAIN CABIN FLOOR SUPPORT IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN MID CABIN FLOOR UNDER FLOOR PANEL 241 GF BETWEEN BS 1160 & 1180, BL 0, SUPPORT BRACKET HAS 2 CRACKS. FABRICATED IAW DRAWING. REMOVED REPLACED IAW SRM 51-70-11-OG-0, AND REINSTALLED MAIN CABIN FLOOR SUPPORT IAW SRM 51-40-02.