What was found
CRACK FOUND AT LT HORIZONTAL STAB LOWER SKIN AT HSS 147.90 , INBD ROW, 15.5" FROM FRONT SPAR. CRACK LENGTH 0.75". REMOVED DAMAGE AT LT HORIZONTAL STAB LOWER SKIN AT HSS 1 47.90" FABRICATED REPAIR PARTS & INSTALLED REPAIR 11 IAW SRM 55-10-01-2R-11, REPAIR 11. REPAIR 11 IS A CATEGORY B REPAIR DUE FOR SUPPLEMENTAL INSPECTIONS FOR DAMAGE TOLERANCE ASSEMENT IAW SRM 55-10-01, PARAGRAPH 5. REPAIR 11.