What was found
EMERGENCY LIGHTS - OPERATIONAL CHECK EMERGENCY LIGHTS OPERATIONAL CHECK - 12A, 2A EPL LIGHT INOP CORRECTION SEAT 12C AND 2C REPLACED 2B EMERGENCY LIGHT REF AMM 33-51-11. CHECK GOOD. SEAT 12C RELAMPED EMERGENCY LIGHT, NO HELP. POSSIBLE WIRE HARNESS INOP REQUST TO DEFER MEL 3319E FOR SEAT 12C. LIGHTS WITHIN TWO SEAT ROWS OPERATE NORMAL. TOMC APPROVED COMPLIED WITH MEL FOUND E.P.L LOCKING CONNECTOR AT SEAT 12B NOT FULLY ENGAGED. RESECURED CONNECTOR. OPS CHECK 12C AISLE PATHWAY LIGHTING PER AMM 33-51-11. OPS CHECK NORMAL. PLACARD REMOVED. MEL CLEARED. OKAY FOR SERVICE. UPDATED FOR SDR INFO.