What was found
FOUND PREVIOUS DAMAGE ON RT OTBD FLAP TRAILING EDGE. REMOVED OLD BONDING MATERIAL. MAPPED DAMAGE DENT IS LOCATED BETWEEN RIBS 7 & 8 LOWER SURFACE APPROX. 3" AFT OF TE SPAR FASTENERS. DENT NOT IN ALLOWABLE LIMITS IAW SRM 57-53-00-283-092, FIG 1, SHEET 1. REFER TO SRM 57-53-00-283-093 FIG 1 SHEET 1 , OUT OF LIMITS FOR PUNCTURES. REFER TO SRM 57-53-00-300-120 ZONE 2 FOR EXTERNAL BONDED METAL DOUBLER & CORE REPAIR. COMPLETED STEPS 2. A. (1) (A) AND (F) OF SRM 57-53-00-300-120. DAMAGED CORE MOSTLY REMOVED BUT NEEDS CLEANED UP. COMPLETED STEPS 2. A. (1) (F) AND (J) OF SRM 57-53-00-300-120. READY FOR ADHEASIVE PRIMER. REMAINING REPAIR WORK WILL BE DONE ON LOGPAGE 7579831 REPAIR DETERMINED TO BE A MINOR REPAIR BY MAINTENANCE.