What was found
POSSIBLE LIGHTING STRIKE ON EXT FUSE FASTENER AT STA 243.7, 10" BELOW STRINGER 16RREMOVED EXISTING FASTENERS COMMON TO REPAIR DOUBLER. ACCOMPLISHED INSP IAW SRM 53-10-01-2R-8 REPAIR STEPS 4.H.(3) AND (4). REMOVED FASTNER HOLES & COUNTERSINKS IAW SRM 53-10-01-2R-8 REPAIR STEPS 4.H.(3) AND (4) IAW NDT PART 6 51-00-00 PROC 16 AND PROC. 4. CUT OUT DAMAGE, BS 243.7, 10 INCHES BELOW S16R. PERFORMED SRM 53-10-01 2R8 PARA 4 STEP F-2. REFER TO 737 NDT PART 6, 51-00-00. PROCEDURE 23 OR PROCEDURE 4. ACCOMPLISHED HFEC OF CUT OUT, REF NTM PT6 51-00-00 PROC 23. NO DEFECTS ACCOMPLISHED .040 INCH INSURANCE CUT IAW SRM 53-10-01-2R-8 STEP F2, PERFORMED A DETAILED INSPECTION OF SKIN AND STRUCTURE IAW SRM 53-10-01-2R-8, STEP H1-4, ACP RII OF INSTALLED REPAIR WITH FASTENERS IAW SRM 53-10-01-2R-8 STEP R. REPAIR IAW SHEET 1, AND GMM 9-25-05. OK TO CONTINUE.