What was found
PERFORM CONDITIONAL INSP IAW AMM TASK 05-51-58-800-801-C3, ACCOMPLISHED CONDITIONAL INSPECTION IAW AMM 05-51-58-800-801-C3. NO SIGNS OF ARCHING OR BURNING. UPON FURTHER VISUAL AND OPS INSPECTION, FOUND OIL ON BOTTOM INTERIOR OF OVEN AND ON HEATING ELEMENT OF OVEN 705. CHECKED ODOR OF OIL AND DETERMINED TO BE COOKING OIL AND SMOKE PRODUCED BY OIL ON HEATING ELEMENT. OIL IS NOT COMING FROM EXTERNAL OR INTERNAL SYS LEAKS. REF L/P 7747753 FOR FURTHER DISPOSITION.