What was found
FA`S REPORT FAINT BURNING ODOR IN FWD GALLEY, ON DESCENT. NO SMOKE OBSERVED. REMOVED & INSPECTED COFFEEMAKER, NO ODOR PRESENT. AS A PRECAUTION R & R THE COFFEEMAKER AT G11 IAW AMM 25-32-01-400-801. OPS CHKD GOOD, NO DEFECTS NOTED. PERFORMED SMOKE OR FUMES IN CABIN SOURCE UNKNOWN. INSPECTED IAW FIM 21-00, TASK 830. NO SMOKE, DEFECTS, OR ODOR NOTED.