What was found
CONDENSER INLET SENSOR R STATUS MSG DISPLAYED, DUE TO LOW LIMIT VALVE R HAS BEEN DEACTIVED IN OPEN POSITION AS REQUIRED PER DDG 21- 52-05. ACPD AS REQUIRED PER DDG 21-52-05. REQUESTING MEL CARD 2152BL. TOMC APPROVES MEL 2152BL FOR RH PACK CONDENSOR INLET SENSOR MSG. COMPLIED WITH MEL 2152BL. PLACARD INSTALLED R LOW LIMIT VLV REPLACED ON LP 7736927. CONDENSER INLET SENSOR CONNECTOR RECONNECTED. NO STATUS MESSAGE AND EXISTING FAULT. MEL REVERSED.