What was found
HORIZONTAL STAB CABLES STA & STAB WERE REPLACED. EA2700-02282 AMM/ 27-41-82-400-801. (FOLLOW UP DIP) DO TO GRADE D STAB CONTROL CABLES STA & STB INSTALLED RE-TENSIONING OF BOTH STAB & STAB CABLES ARE REQUIRED IAW APPLICABLE AMM AFTER 3 MONTHS BUT NOT TO EXCEED 4 MONTHS FROM THE ACCOMPLISHMENT OF TASK. MCO MX REPLACED HORIZONTAL STAB CABLES STA AND STB GRADE D CABLE ASSY WITH HIGH ZINC COATING.