What was found
MAIN DECK FLOOR AREA ADJACENT TO R1 DOOR SILL BET. STA 324 - 377 INTERCOSTAL UPPER SKIN CORRODED. 16-23. REF NRC 136578. COMPLETED SFR REPORTING ONLY REMOVED AND REPLACED 02EA INTERCOSTAL AT MAIN DECK FLOOR AREA R1 DOOR SILL IAW SRM 51-40-0-0G-0.