As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING EMERGENCY LIGHT TEST, FOUND LT FWD EXIT LIGHT OUT. TROUBLESHOT AND FOUND ONE FUSE ON EMERGENCY POWER SUPPLY M1694 IS OPEN. REMOVED AND REPLACED UNSERVICEABLE FUSE IAW AMM 33-51-06-960-804. PERFORMED TEST ON FUSE IAW AMM 33-51-06-710-003. CHECKED GOOD. LT FWD EXIT EMERGENCY LIGHT OPS FOUND NORMAL.