What was found
DURING APPROACH, TE FLAP DISAGREE BETWEEN FLAPS 25 TO 30. RETRACTED TO 20DRG GA AND EICAS CLRD INSPECTED LEADING EDGE AND TRAILING EDGE FLAPS NO DEFECTS NOTED. NO EICAS MESSAGE ON ARRIVAL.FLAPS OPERATE NORMALLY HYDRAULICALLY AND ELECTRICALLY. PERFORMED FSEU BITE FAULT 303 NOTED . PERFORMED TEST OF THE POSITION INDICATING SYSTEM FOR THE TE FLAPS IAW TASK 27-58-00-705-001REV -. NO DEFECTS OR FAULTS NOTED. ALL FSEU BITE PASSED FIM 27-51-FAULT TREE 805 T/S PER FIM.