What was found
FWD WET AREA FLOOR SUPPORT BS 294.5-312, RBL 10 WITH CORROSION AT FASTENER HOLES. REMOVED AND REPLACED THE FLOOR SUPPORT AT FWD WET AREA FLOOR STRUCTURE BETWEEN BS 294.5 TO BS 312, RBL 10 IAW SRM 51-40-02-0G-0 AND DWG 141A5410.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD WET AREA FLOOR SUPPORT BS 294.5-312, RBL 10 WITH CORROSION AT FASTENER HOLES. REMOVED AND REPLACED THE FLOOR SUPPORT AT FWD WET AREA FLOOR STRUCTURE BETWEEN BS 294.5 TO BS 312, RBL 10 IAW SRM 51-40-02-0G-0 AND DWG 141A5410.