What was found
DURING OK TO CLOSE FOUND LOWER WTB FAIRING STRUCTURE ANGLE AT STA 900 LBL 7 WITH CRACK. REMOVED ANGLE IAW SRM 51-40-02, FABRICATED ANGLE SUPPORT, IAW DWG 149N7130, LOCATED & DRILLED IAW SRM 51-40-05. APPLIED RESTORED SURFACE PROTECTION IAW AMM 51-21-04-107-017, AMM 51-21-14-370-804, & AMM 51-21-04-110-801, INSTALLED THE SUPPORT ANGLE IAW SRM 51-40-02-0G-0.