What was found
APU INLET DOOR CUTOUT AND A BOLT, UPPER AFT CORNER HAVE EVIDENCE OF CORROSION. PERFORMED REPAIR ON THE APU INLET DOOR CUT OUT SURROUND STRUCTIR E AT STA 1825 IAW B757-200 SRM 53-80-15-2R-1 REPAIR 1 DETAIL 1 WC: 140920.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU INLET DOOR CUTOUT AND A BOLT, UPPER AFT CORNER HAVE EVIDENCE OF CORROSION. PERFORMED REPAIR ON THE APU INLET DOOR CUT OUT SURROUND STRUCTIR E AT STA 1825 IAW B757-200 SRM 53-80-15-2R-1 REPAIR 1 DETAIL 1 WC: 140920.