What was found
UNUSUAL ODOR THROUGHOUT PLANE ESPECIALLY NEAR FRONT. NOTED VERY STRONG ELECTRICAL BURNING ODOR COMING FROM FLIGHTDECK AND FWD E & E AREA REPLACED LT & RT RECIRCULATION AIR FILTERS IAW TASK 21-25-01-400-801. INSPECTED FWD GALLEY AREA LIGHTS. ENTRY LIGHTS, NO FF. OPS CHECKED FLT DECK INSTRUMENTS, DOME LIGHTS, RADAR, NFF. INSPECTED P91 & P92 PANELS, NO DEFECTS NOTED. INSPECTED AROUND FWD E & E, NO DEFECTS. DETERMINED TO THE NEW INTERIOR MOD ACCOMPD RFD STATION ON 03/07/26 CAUSED ALL THE ABNORMAL ODORS, ESPESCIALLY AT FWD GALLEY FLOOR RUBBER MAT. STRONGER ODOR WHEN ACFT STAYS IN SUN. ODOR GOES AWAY WHEN AC PACKS ON.