What was found
FOUND CORRODED AFT CARGO BAY FLOOR SUPPORT SHIELD S25R BETWEEN BS 767 & 787. INSTALLED A NEW SHIELD IAW SRM 51-40-02-0G-0, & DWG 146A0081.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CORRODED AFT CARGO BAY FLOOR SUPPORT SHIELD S25R BETWEEN BS 767 & 787. INSTALLED A NEW SHIELD IAW SRM 51-40-02-0G-0, & DWG 146A0081.