What was found
LEFT HORIZONTAL STAB, AT STAB STA 92.70 INBD SIDE OF RIB HAS ONE CRACK IN NR 3 VERTICAL STIFFINER LOWER TRANSITION RADIUS. CUT AND REMOVED THE DAMAGE FROM THE VERTICAL STIFFNER IAW SRM 55-10-09-2R-4. ACCOMPLISHED SURFACE HFEC INSP IAW NTM 51-00-00, PROCEDURE 23, FABRICATED REPAIR PARTS -1 T-SECTION, -2 ANGLE AND -3 SHIM IAW SRM 55-10-09-2R-4. ALODINED AND PRIMED REPAIR PARTS IAW SRM 51-20-01. INSTALLED REPAIR PARTS IAW SRM 55-10-09-2R-4.