Service difficulty report · Pump · Boeing 767322

Difficulty date
March 27, 2026
Submitted
March 30, 2026
Operation
Air carrier
Aircraft
N657UA
Make and model
Boeing 767322
Aircraft serial
27112
Aircraft time
128,333 hours, 19,625 cycles
Part
Pump
Part number
3508806
Part serial
MX512039
Condition
Faulted
Location
Hyd Sys
Part time
500,804 hours, 500,111 cycles
Stage of operation
CR
How discovered
O
Nature of condition
K, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

R HYD QTY EICAS FOLLOW- ED BY R HYD SYS PRESS R HYD QTY READS 0FOUND HYD CASE DRAIN HOSE BLOWN. R & R HYD CASE DRAIN HOSE PER AMM SUB TASK 71-00-02-420-057-C7 WHILE LEAK CHECKING HYD CASE DRAIN HOSE DURING ENG RUN THE EDP NEVER CAME ON. R & R RT SYS RETURN FILTER. STILL REQUIRES LEAK CHK TO BE PERFORMED AFTER PUMP CHANGE. NO DEBRIS WERE FOUND ON OLD FILTER ELEMENT REF AMM 29-11-17/401. REMOVED RT EDP PRESSURE & CASE DRAIN FILTERS & INSPECTED FOR DEBRIS. NONE FOUND. INSTALLED NEW FILTER ELEMENTS. STILL REQUIRES LEAK CHECKS AFTER PUMP REPLACEMENT. REF STEP - NO MANUAL. REMOVED #2 ENG EDP UP TO AND INCLUDING STEP D.(15) REF AMM 29-11-05-004-001-005 CONTINUED OF THE REMOVAL OF THE #2 ENG EDP FROM STEP D.(16), REF AMM 29-11-05-004-001-005. REPLACED #2 ENG EDP, REF AMM 29-11-05-404-029-005. OPS & LEAK CHKD GOOD, OK TO CONTINUE.