What was found
RIGHT FWD LATCH FOR DOOR 192 DR HAS WORN INTO CHORD ALMOST ALL THE WAY THROUGH.MARKED MAJOR REPAIR AND INITIATED SFR. INITIATED SDR REMOVED DOOR 192 DR, ECS DOOR SEAL AND RETAINER FOR ACCESS TO SHEETMETAL REPAIR.REF SRM 57-10-13-2R-3. STEP 4A. COMPLIED WITH STEPS 4 A-E REF SRM 57-10-13-2R-3, STEP F REQUIRES HFEC FOR CUTOUT EDGE REF 737NDT MANUAL PART 6 PROCEEDURE 4 OR 6. STEP G REQUIRES OPEN HOLE HFEC REF 737 NDT MANUAL PART 6 PROCEEDURE 16 FOR 5/32 NUTPLATE HOLES. PERFORMED RII FOR HOLE HFEC NDT PART 6 51-00-00 PRO16 NO DEFE FABRICATED FILLER AND STRAP IAW SRM 57-13-00 ACCOMPLISHED FLAP PEEN OF CUT-OUT AREA OF CHORD. IAW SRM. 53-10-13-2R-3 REPAIR 3, PARA. 4.H.(3) OPS CK GOOD