What was found
AFT CARGO COMAPRTMENT, RT FLOOR STRUCTURE SHIELD BETWEEN BS 767 & 787, STRINGER 24R. FOUND EXCESSIVE CORROSION. REMOVED AND REPLACED THE SHIELD IN THE AFT CARGO BAY IAW SRM 51-40-02-0G-0, 51-40-05-0G-0, 51-40-08-0G-0, DWG 146A0081, REV A, DWG 46A8127 REV -, DWG 146A8127 REV C, AMM 51-21-41-370-802, 51-21-72-370-804.