What was found
ENG 1 SOURCE OFF LIGHT ILLUMINATED ENG 1 IDG FAULT LIGHT ON GENERATOR CONTROL UNIT. REPLACED ENG 1 IDG REF AMM 24-11-11. OPS CHECK, LOAD TEST, LEAK TEST AND DISCONNECT TEST SUCCESSFUL REF AMM 24-11-00. ACCOMPLISHED ALL REQUIRED IDT INSPECTION FOR E-1 IDG REMOVE AND REPLACE. REF GMM 09-10-05 & AMM 24-11-00