What was found
C HYD DEMAND PUMP EICAS W/FLAP RETRACTION TOMC HAS ORDERED PARTS TO IAD FOR FIM TASKS: ADP LOW PRESSURE LIGHT IS ON IN AUTO MODE OR MANUAL MODEREFERENCE: 29-11 FAULT TREE 898 FOLLOWED FIM TASK 29-11 FAULT TREE 898 PERFORMED CONTINUITY CHECK BETWEEN PIN 2 AND 3. FOUND CONTINUITY BETWEEN THE PINS. FIM SAYS REPLACE ADP CONTROL PRESSURE SWITCH S29. IADMM WORKING ITEM PILOT DEBRIEF: PILOT STATED THAT LANDING WAS SMOOTH. R&R S29 PRESSURE SWITCH REF AMM 29-11-19. PERFORMED OPS TEST OF MAIN HYDRAULIC SYSTEMS OPS CHECK GOOD AT THIS TIME.