What was found
RIGHT MLG CENTER DOOR FRAME CRACKED NEAR THE LOWER FORWARD ATTACH POINT. REMOVED RT MLG DOOR ASSY IAW AMM 32-13-11-000-803, REPAIR PARTS IAW SRM 52-80-02-2R-2 AND SRM 51-40-02-0G-0 .REINSTALLED RT MLG DOOR ASSY IAW AMM 32-13-11-420 -803. ACCOMPLISHED RT MLG SHOCKS STRUT DOOR ADJUSTMENT IAW AMM 32-13-11-820-801.CLEARANCES AND FLUSHNES WITHIN LIMITS. ACCOMPLISHED MLG OPS TEST IAW AMM 32-32 -00-710-801, TESTED OK