What was found
CRACK FOUND AT LT INTERNAL SKIN, BELOW 2ND FASTENER HOLE. LOCATED AFT OF BS 663.75 FRAME FITTING ASSY UNDER S18L. CRACK LENGTH : 1.4. ACCOMPLISHED REPAIR TO THE LT INTERNAL SKIN. ACCOMPLISHED REPAIR AT L/H INTERNAL SKIN BELOW 2ND FASTENER HOLE LOCATED AFT OF STA. 663.75 FRAME FITTING ASSEMBLY UNDER S-18L REF ESR # 51-14851AND COMPLIANCE WITH THE REQUIREMENTS OF ESR-WI 51-14851 AND ECRA 5340-02263 WERE ACHIEVED.