What was found
FORWARD ENTRY DOOR, LOWER GATE, GATE UNDER FAIRED. GAP EXISTS BETWEEN THRESHOLD AND GATE. STARTED ADJUSTMENT OF LOWER GATE REF AMM 52-11-00-820-801 ITEM 2.N. LENGTHENED LOWER GATE CONTROL ROD BY TURNING THE ROD END BEARING 4 FULL TURNS. GAP IS OUT OF LIMITS REF NOTED AMM ITEM 2.N.(1)(B). APPLYING MORE THEN 4 FULL TURNS RESULTS IN STIFFENING UP HANDLE MOVEMENT. NUT/BOLT COMMON TO LOWER GATE CONTOL ROD END BEARING AND GATE CLEVIS IS NOT TORQUED/SAFETIED; "FINGER TIGHT" ONLY. PREFORMED UPPER AND LOWER GATE ADJUSTMENT PER AMM 52-11-00-820-801 STEP 2. N. (1), UPPER AND LOWER GATE FLUSHNESS NOW WITHIN LIMITS PER AMM 52-11-00-820-801 TABLE 502 ZONE B AND F ACCOMPLISHED INSPECTION OF UPPER AND LOWER GATE ADJUSTMENT PER AMM 52-11-00-820-801. MEASUREMENTS WITHIN LIMITS.