What was found
FOUND CRACK L/W FRONT SPAR INB END TO BODY FAIRING "U" ANGLE CRACKED ATTACHED TO FIXED L/E FAIRING - MKD DOT 002 REF. AAR N/R:100024822 STEP CREATED TO DOCUMENT CORRECTIVE ACTION,REMOVED AND REPLACED L/W FRONT SPAR INB END TO BODY FAIRING FRAME REF SRM 51-4-02-0G-0,AND DWG 116A3110,PENDING ESFR ENTRY AND NO DIP REQUIRED.WORK ACCOMPLISHED BY:V937360 ADD EMP:V894534 INSPECTED BY Q.C:V919797 ( INSP-250 ) CREATED SFR REMOVED AND REPLACED U ANGLE (FRAME) AT L/W FRONT SPAR INB END TO BODY FAIRING ATTACHED TO FIXED L/E FAIRING IAW SRM 51-40-02-0G-0 AND DWG#116A3010.