As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ACCESS PANEL 139AL FORWARD KEEL BEAM REQUIRE FURTHER CLEANING AT PANEL ATTACH FRAMES AND CHECK ON CORROSION. CLEANED AREA IAW SOPM 20-30-03. REMOVED CORROSION IAW SRM 51-10-02-0G-0. ORIGINAL THICKNESS .130", REMAINING THI CKNESS .123" FOUND TO BE WITHIN LIMITS. IAW SRM 53-00-7 1-1A-1. REMOVED AND REPLACED SPLICE ANGLE IAW SRM 51-40-02-0G-0.