What was found
RH MLG LWR OB BORE OF FWD TRUNION SUPPORT SCRATCHES. REAMED THE RH MLG LWR O/B BORE OF FWD TRUNION SUPPORT TO 1.5799", FOUND TO BE WITHIN LIMITS IAW SRM 57-20-90-2R-2 STEP 4. 51-20-01-0G-0 & SOPM 20-30-03. NO MORE DAMAGE FOUND .
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RH MLG LWR OB BORE OF FWD TRUNION SUPPORT SCRATCHES. REAMED THE RH MLG LWR O/B BORE OF FWD TRUNION SUPPORT TO 1.5799", FOUND TO BE WITHIN LIMITS IAW SRM 57-20-90-2R-2 STEP 4. 51-20-01-0G-0 & SOPM 20-30-03. NO MORE DAMAGE FOUND .